Review



microfluidic device  (Chemyx Inc)


Bioz Verified Symbol Chemyx Inc is a verified supplier
Bioz Manufacturer Symbol Chemyx Inc manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 95

    Structured Review

    Chemyx Inc microfluidic device
    <t>Microfluidics</t> device design and fabrication. (A) Photograph of the microfluidics device. (B) Cartoon representation of the microfluidics device used in these studies. The general layout is shown with the 3 inlet and outlet ports labeled. The dual Herringbone structures for efficient solution mixing are also shown. (C) Device fabrication flowchart. The flowchart includes all steps for device construction as well as pretreatment for MS analysis.
    Microfluidic Device, supplied by Chemyx Inc, used in various techniques. Bioz Stars score: 95/100, based on 127 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/microfluidic+device/Fusion+6000/pmc13177252-104-7-15
    Average 95 stars, based on 127 article reviews
    microfluidic device - by Bioz Stars, 2026-10
    95/100 stars

    Images

    1) Product Images from "Integrating Simple Microfluidics Design/Fabrication with a Novel Ionization Source for Time-Resolved Chemical Reaction Studies by Mass Spectrometry"

    Article Title: Integrating Simple Microfluidics Design/Fabrication with a Novel Ionization Source for Time-Resolved Chemical Reaction Studies by Mass Spectrometry

    Journal: ACS Omega

    doi: 10.1021/acsomega.5c12681

    Microfluidics device design and fabrication. (A) Photograph of the microfluidics device. (B) Cartoon representation of the microfluidics device used in these studies. The general layout is shown with the 3 inlet and outlet ports labeled. The dual Herringbone structures for efficient solution mixing are also shown. (C) Device fabrication flowchart. The flowchart includes all steps for device construction as well as pretreatment for MS analysis.
    Figure Legend Snippet: Microfluidics device design and fabrication. (A) Photograph of the microfluidics device. (B) Cartoon representation of the microfluidics device used in these studies. The general layout is shown with the 3 inlet and outlet ports labeled. The dual Herringbone structures for efficient solution mixing are also shown. (C) Device fabrication flowchart. The flowchart includes all steps for device construction as well as pretreatment for MS analysis.

    Techniques Used: Labeling

    Total deuterium uptake of the microfluidics setup employing different total flow rates. The PTFE tubing length associated with each flow rate is provided above the respective data point. The dashed line shows the weighted m / z value of unreacted myoglobin 14+ ions. Error bars represent one standard deviation about the mean for triplicate measurements.
    Figure Legend Snippet: Total deuterium uptake of the microfluidics setup employing different total flow rates. The PTFE tubing length associated with each flow rate is provided above the respective data point. The dashed line shows the weighted m / z value of unreacted myoglobin 14+ ions. Error bars represent one standard deviation about the mean for triplicate measurements.

    Techniques Used: Standard Deviation

    Related Articles

    Injection:

    Article Title: Integrating Simple Microfluidics Design/Fabrication with a Novel Ionization Source for Time-Resolved Chemical Reaction Studies by Mass Spectrometry
    Article Snippet: .. All three solutions were injected into the microfluidic device using two Fusion 6000 syringe pumps (Chemyx, Stafford, TX) before connecting to the cVSSI device via tubing. .. Once tubing was connected to the cVSSI device, ionization was initiated through a 33500B Series waveform generator (Keysight; Santa Rosa, CA) set to sine wave frequency (89–91 kHz, 85 mV pp ) coupled to a model 7500 amplifier (Krohnhite; Brockton, MA) set to 100×.

    Article Title: Student-Fabricated Microfluidic Devices as Flow Reactors for Organic and Inorganic Synthesis
    Article Snippet: Flow synthesis in microfluidic devices has been rapidly adapted in the pharmaceutical industry and in many research laboratories.. Yet, the cost of commercial flow reactors is a major factor limiting the dissemination of this technology in the undergraduate curriculum.. Here, we present a laboratory activity where students design and fabricate homemade microfluidic flow reactors using thermoplastic molds and soft lithographic methods, and conduct inorganic syntheses of magnetite particles and gold− citrate nanoparticles, as well as a two-step organic synthesis of azo dyes.



    Similar Products

    96
    Malvern Panalytical wave system microfluidics device
    Wave System Microfluidics Device, supplied by Malvern Panalytical, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/microfluidic+device/WAVEsystem/pm42775468-108-9-13
    Average 96 stars, based on 1 article reviews
    wave system microfluidics device - by Bioz Stars, 2026-10
    96/100 stars
      Buy from Supplier

    86
    10X Genomics chromium microfluidic device
    Chromium Microfluidic Device, supplied by 10X Genomics, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/microfluidic+device/chips+chromium+microfluidic/pmc09383695-54-31-29
    Average 86 stars, based on 1 article reviews
    chromium microfluidic device - by Bioz Stars, 2026-10
    86/100 stars
      Buy from Supplier

    86
    Deepak Inc portable microfluidic colorimetric device
    Portable Microfluidic Colorimetric Device, supplied by Deepak Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/microfluidic+device/colorimetric+device+microfluidic+portable/pm42270267-65-7-1
    Average 86 stars, based on 1 article reviews
    portable microfluidic colorimetric device - by Bioz Stars, 2026-10
    86/100 stars
      Buy from Supplier

    86
    Singleron Biotechnologies microfluidic devices
    Microfluidic Devices, supplied by Singleron Biotechnologies, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/microfluidic+device/chip+microfluidic/pm42234562-306-6-34
    Average 86 stars, based on 1 article reviews
    microfluidic devices - by Bioz Stars, 2026-10
    86/100 stars
      Buy from Supplier

    86
    10X Genomics chromiumtm microfluidics device
    Chromiumtm Microfluidics Device, supplied by 10X Genomics, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/microfluidic+device/device+microfluidics/us12624091-537-12-15
    Average 86 stars, based on 1 article reviews
    chromiumtm microfluidics device - by Bioz Stars, 2026-10
    86/100 stars
      Buy from Supplier

    86
    Autodesk Inc microfluidic devices
    Microfluidic Devices, supplied by Autodesk Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/microfluidic+device/devices+microfluidic/pm42121382-32-0-7
    Average 86 stars, based on 1 article reviews
    microfluidic devices - by Bioz Stars, 2026-10
    86/100 stars
      Buy from Supplier

    86
    Autodesk Inc multilayer microfluidic device
    Multilayer Microfluidic Device, supplied by Autodesk Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/microfluidic+device/devices+microfluidic/pm42120884-220-1-7
    Average 86 stars, based on 1 article reviews
    multilayer microfluidic device - by Bioz Stars, 2026-10
    86/100 stars
      Buy from Supplier

    95
    Chemyx Inc microfluidic device
    <t>Microfluidics</t> device design and fabrication. (A) Photograph of the microfluidics device. (B) Cartoon representation of the microfluidics device used in these studies. The general layout is shown with the 3 inlet and outlet ports labeled. The dual Herringbone structures for efficient solution mixing are also shown. (C) Device fabrication flowchart. The flowchart includes all steps for device construction as well as pretreatment for MS analysis.
    Microfluidic Device, supplied by Chemyx Inc, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/microfluidic+device/Fusion+6000/pmc13177252-104-7-15
    Average 95 stars, based on 1 article reviews
    microfluidic device - by Bioz Stars, 2026-10
    95/100 stars
      Buy from Supplier

    Image Search Results


    Microfluidics device design and fabrication. (A) Photograph of the microfluidics device. (B) Cartoon representation of the microfluidics device used in these studies. The general layout is shown with the 3 inlet and outlet ports labeled. The dual Herringbone structures for efficient solution mixing are also shown. (C) Device fabrication flowchart. The flowchart includes all steps for device construction as well as pretreatment for MS analysis.

    Journal: ACS Omega

    Article Title: Integrating Simple Microfluidics Design/Fabrication with a Novel Ionization Source for Time-Resolved Chemical Reaction Studies by Mass Spectrometry

    doi: 10.1021/acsomega.5c12681

    Figure Lengend Snippet: Microfluidics device design and fabrication. (A) Photograph of the microfluidics device. (B) Cartoon representation of the microfluidics device used in these studies. The general layout is shown with the 3 inlet and outlet ports labeled. The dual Herringbone structures for efficient solution mixing are also shown. (C) Device fabrication flowchart. The flowchart includes all steps for device construction as well as pretreatment for MS analysis.

    Article Snippet: All three solutions were injected into the microfluidic device using two Fusion 6000 syringe pumps (Chemyx, Stafford, TX) before connecting to the cVSSI device via tubing.

    Techniques: Labeling

    Total deuterium uptake of the microfluidics setup employing different total flow rates. The PTFE tubing length associated with each flow rate is provided above the respective data point. The dashed line shows the weighted m / z value of unreacted myoglobin 14+ ions. Error bars represent one standard deviation about the mean for triplicate measurements.

    Journal: ACS Omega

    Article Title: Integrating Simple Microfluidics Design/Fabrication with a Novel Ionization Source for Time-Resolved Chemical Reaction Studies by Mass Spectrometry

    doi: 10.1021/acsomega.5c12681

    Figure Lengend Snippet: Total deuterium uptake of the microfluidics setup employing different total flow rates. The PTFE tubing length associated with each flow rate is provided above the respective data point. The dashed line shows the weighted m / z value of unreacted myoglobin 14+ ions. Error bars represent one standard deviation about the mean for triplicate measurements.

    Article Snippet: All three solutions were injected into the microfluidic device using two Fusion 6000 syringe pumps (Chemyx, Stafford, TX) before connecting to the cVSSI device via tubing.

    Techniques: Standard Deviation